    NOTE: This model is discontinued.  Please call 888-681-3082 for replacement model.

    Presenting the 10.3 cu. ft. capacity Ultima II Cryogenic Chest Freezer from Thermo Scientific Revco. ULT10140-9-E has temperature range of -140 degrees C, safely below the -130 C glass transition temperature ideal for the most critical material storage. Its advanced technology monitoring system features multiple functions like the Lifeguard compressor protection that monitors performance and automatically adjusts to internal and external conditions, the extreme ambient alert that warns if room temperature can affect performance and the voltage boost indicator that advises of low source voltage below safe parameters and indicates when voltage boost system is activated. It also has an on-board power monitoring with digital readout of incoming line voltage and a built-in surge suppressor with a "Clean Filter" indicator. Additionally, its foamed-in-place closed-cell, CFC-free urethane insulation and recessed heavy-duty swivel casters provide enhanced performance and easy mobility.

    Specifications
    Thermo Scientific Revco Ultima II Cryogenic Chest Freezer ULT10140-9-E Specifications
    Capacity10.3 Cu. Ft. (292 Liters)
    Interior Dimensions26.5" H x 19.0" D x 35.25" W (670 x 480 x 890 mm)
    Exterior Dimensions42.75" H x 29.0" D x 69.0" W (1090 x 740 x 1760 mm)
    Temperature Range-140 C
    Temperature ControlMicroprocessor
    DefrostManual
    RefrigerantCFC-Free
    Refrigeration SystemHigh-capacity, air-cooled autocascade
    ColorWhite
    CabinetHeavy-gauge steel with high-impact powder paint finish
    Electrical Requirements 208 - 230 V / 60 Hz
    Phase3
    LidsHeavy-duty counterbalanced lid with integrated keyed lock and insulated sublids
    Box Weight1065 Lbs. (483 Kg)
    WarrantyUS: 24-month warranty, parts and labor (total five-year warranty on compressor parts).
    International: 16-month warranty,parts.
    Features

    Thermo Scientific Revco Ultima II Cryogenic Chest Freezer ULT10140-9-E Features:

    • Top-to-bottom temperature uniformity is dramatically improved when compared to LN2 vapor. Cell viability is improved because biologically relevant, thermally driven reactions are not known to occur.
    • Uniform temperature of -140 C, safely below the -130 C glass transition temperature
    • Manual defrost
    • Refrigeration System
      Exclusive mixed refrigerant autocascade with a single, orbital air-cooled compressor
      CFC-free refrigerants
      Downfeed evaporator for most efficient refrigerant flow
      High-capacity air-cooled condenser with dual condenser fans, aerodynamically shaped fan blades
      Washable condenser filter keeps fins free of dust to maintain peak cooling efficiency; no tools required for removal
    • IntrLogic Microprocessor Control System
      Touchpad data entry with digital display of all functions
      Key-operated main power and alarm switch for setpoint security
      Setpoints adjustable in 1 C increments
      Independent operating temperature and high/low limit alarm functions with factory-set defaults for quick start-up
    • Alarm System
      Power failure or temperature deviation triggers audible and visual warning
      Automatic Incident Monitor identifies temperature deviation beyond alarm setpoints
      Adjustable safety alarm with automatic, continuous charge battery backup
      Digital battery indicator
      Touchpad alarm test function
      RS-232 data port with system software
      Exterior alarm contacts for connection to remote monitoring system
    • Monitoring System
      Lifeguard compressor protection monitors performance and automatically adjusts to internal and external conditions
      Extreme Ambient Alert warns if room temperature can affect performance
      Voltage Boost Indicator advises of low source voltage below safe parameters and indicates voltage boost system is activated
      On-board power monitoring with digital readout of incoming line voltage
      Built-in surge suppressor
      "Clean Filter" indicator
    • Construction
      Low-profile design for easy access to inventory
      Heavy-gauge steel cabinet with high-impact powder paint finish
      Heavy-duty counterbalanced lid with integrated keyed lock and independent sublids
      Double-seal lid gaskets minimize frost buildup
      Minimum 5 in. (12.7cm) foamed-in-place closed-cell, CFC-free urethane insulation
      Access port, 1 in. (2.54cm) diameter, with cap
      Recessed heavy-duty swivel casters
      100% of interior space is usable, with stored samples maintained below critical temperature
      Ample interior volume with capacity of up to 21,600 samples (2 ml vials in boxes)
      Uses standard Thermo Scientific Revco inventory racks and fiberboard boxes
    • Compliance: UL, cUL listed.
    Short Specifications
    ULT10140-9-E Thermo Scientific Revco Thermo Scientific Revco Ultima II Cryogenic Chest Freezer (-140 C) 10.3 Cu. Ft. ULT10140-9-E, Cryogenic Storage Systems - Medical Appliances.
    • 208 / 230 V Cryogenic Chest Freezer
    • 10.3 Cu. Ft. Capacity
    • Temperature Range: -140 C
    • Manual Defrost